{"id":8706,"date":"2026-05-15T09:43:54","date_gmt":"2026-05-15T01:43:54","guid":{"rendered":"https:\/\/www.ledtestsystem.com\/?p=8706"},"modified":"2026-05-15T09:43:54","modified_gmt":"2026-05-15T01:43:54","slug":"advanced-light-and-color-meter-applications-for-quality-control","status":"publish","type":"post","link":"https:\/\/ledtestsystem.com\/ja\/%e3%83%96%e3%83%ad%e3%82%b0\/advanced-light-and-color-meter-applications-for-quality-control\/","title":{"rendered":"Advanced Light and Color Meter Applications for Quality Control"},"content":{"rendered":"<p><strong>Title:<\/strong> Advanced Light and Color Meter Applications for Quality Control: Precision Spectroradiometric Analysis with the <a href=\"https:\/\/www.lisungroup.com\/\" target=\"_blank\" rel=\"noopener\">\u30ea\u30b9\u30f3<\/a> LMS-6000 Series<\/p>\n<p><strong>\u62bd\u8c61\u7684\u306a<\/strong><br \/>\nThe measurement of light and color parameters is fundamental to quality control (QC) across a spectrum of high-precision industries. Traditional photometric sensors often fail to capture the spectral nuances required for rigorous pass\/fail criteria. This article presents a technical examination of advanced light and color meter applications, focusing on spectroradiometric instrumentation. We detail the operational principles, metrological specifications, and sector-specific use cases of the LISUN LMS-6000 <a href=\"https:\/\/www.lisungroup.com\/products\/spectroradiometer\/portable-ccd-spectroradiometer.html\" target=\"_blank\" rel=\"noopener\">\u5206\u5149\u653e\u5c04\u8a08<\/a> platform, including its variants (LMS-6000, LMS-6000F, LMS-6000S, LMS-6000P, LMS-6000UV, and LMS-6000SF). The discussion encompasses application in the lighting, automotive, aerospace, display, photovoltaic, and medical equipment industries, supported by standards compliance data and comparative performance metrics.<\/p>\n<p><strong>1. Metrological Foundation: High-Resolution Spectral Scanning vs. Tristimulus Methods<\/strong><\/p>\n<p>Quality control in optical engineering demands more than integrated photopic flux measurements. Tristimulus colorimeters, while fast, suffer from inherent metameric error due to their reliance on broadband filtered detectors. For applications requiring absolute spectral fidelity\u2014such as a precise, traceable chromaticity coordinate or Color Rendering Index (CRI) calculation\u2014a scanning spectroradiometer is indispensable.<\/p>\n<p>The LISUN LMS-6000 series (LMS-6000, LMS-6000F, LMS-6000S, LMS-6000P, LMS-6000UV, and LMS-6000SF) operates on a double monochromator optical design. This structure reduces stray light to below 1\u00d710\u207b\u2075, enabling accurate measurement of low-intensity spectral features adjacent to high-intensity peaks, a critical requirement in LED phosphor characterization. The instrument captures spectral power distributions (SPDs) across a configurable range, typically 380\u2013780 nm for standard visible applications, with an extension to 200\u20131100 nm in the LMS-6000UV variant for ultraviolet and near-infrared analysis. The measurement principle relies on a cooled CCD array or photomultiplier tube (PMT) detector, depending on the variant, ensuring high signal-to-noise ratios (SNR &gt; 1000:1) even at low luminance levels (down to 0.01 cd\/m\u00b2).<\/p>\n<p><strong>2. Spectral Integrity in LED &amp; OLED Manufacturing: Characterizing Phosphor Conversion Efficiency<\/strong><\/p>\n<p>In the solid-state lighting manufacturing sector, binning LEDs by chromaticity and luminous flux is a standard QC procedure. However, the shift from photometric binning to spectral binning has become necessary to ensure color consistency across production lots.<\/p>\n<p>The LMS-6000S variant, optimized for standard LED measurement, provides a wavelength accuracy of \u00b10.3 nm, enabling manufacturers to detect minute shifts in peak wavelength due to junction temperature variation or phosphor degradation. For instance, a 1 nm shift in a blue pump LED can alter the correlated color temperature (CCT) of a white LED by over 50 K, a deviation unacceptable for high-end architectural lighting. Using the device, QC engineers can compute precise values for CRI (Ra and R1\u2013R15), TM-30 metrics (Rf and Rg), and the IES TM-21 lumen maintenance projection by capturing the initial SPD at a 1 nm interval. The instrument\u2019s integral software allows for automated pass\/fail thresholds based on MacAdam ellipse tolerance limits, reducing visual inspection subjectivity.<\/p>\n<p><strong>3. Automotive Lighting Testing: Compliance with SAE J578 and ECE R112 Standards<\/strong><\/p>\n<p>Automotive forward-lighting and signaling systems require rigorous photometric and colorimetric validation. The LMS-6000F variant, featuring a fiber-optic input and cosine-corrected receptor, is particularly suited for goniometric setups used in headlamp testing.<\/p>\n<p>Standard ECE R112 mandates that the chromaticity of dipped-beam headlamps, when measured at defined test points (e.g., 50V, 75R), must fall within a specific white region on the CIE 1931 chromaticity diagram. The spectroradiometer\u2019s stray light rejection capability is critical here; the reflection from optical baffles within the testing apparatus can introduce spurious spectral artifacts. Using the LMS-6000F, test engineers can capture the SPD at each photometric test point with a measurement speed of under 5 seconds per point. The system\u2019s internal calibration against a NIST-traceable standard lamp ensures that luminance measurements (in candela per square meter) are traceable within \u00b12% uncertainty. Additionally, for adaptive driving beam (ADB) systems that rely on pixelated LED matrices, the sensor\u2019s small measurement aperture (selectable down to 0.5\u00b0) allows for high-spatial-resolution analysis of glare zones and cutoff sharpness.<\/p>\n<p><strong>4. Aerospace and Aviation Lighting: Visibility Thresholds and Chromaticity Boundary Verification<\/strong><\/p>\n<p>Aviation lighting\u2014including runway edge lights, taxiway centerline lights, and obstruction beacons\u2014operates under strict chromaticity specifications defined by ICAO Annex 14 and FAA AC 150\/5345-53. The allowed chromaticity boundaries for red, green, yellow, and white aviation lights are extremely narrow to ensure visual contrast against ambient backgrounds.<\/p>\n<p>The LMS-6000 series, with its dual-monochromator architecture, provides the spectral resolution needed to confirm that a light source does not drift into a prohibited chromaticity region as it ages. For example, a red LED obstruction light initially compliant at x=0.685, y=0.315 may, through degradation of the encapsulant, shift to a shorter wavelength, becoming orange-red and failing the ICAO \u201cred\u201d chromaticity parallelogram. The spectroradiometer\u2019s ability to measure at low light levels (down to 0.01 lux for illuminance) is also essential for evaluating night-vision imaging system (NVIS) compatibility in cockpit displays, where spectral leakage in the near-IR region (600\u2013900 nm) must be suppressed by a factor of 10\u2076.<\/p>\n<p><strong>5. Display Equipment Testing: Gamma Curve, Color Gamut, and Uniformity Metrics<\/strong><\/p>\n<p>Flat-panel display manufacturing (LCD, OLED, MicroLED) requires color calibration and uniformity analysis across the entire display area. The LMS-6000P variant, equipped with a precision photometric probe, is designed for contact or near-contact measurement of emissive displays.<\/p>\n<p>The instrument measures the SPD at each gray level (0\u2013255) to derive the true gamma curve, rather than relying on an assumed power-law relationship. This is vital for professional monitors used in graphic arts or medical imaging (DICOM Part 14 compliance). For gamut analysis, the device calculates the color space coverage (e.g., DCI-P3, BT.2020, Adobe RGB) by integrating the measured primaries\u2019 SPDs. The low light performance of the detector allows for accurate measurement of black level luminance in OLED panels, which is critical for contrast ratio determination. Using a motorized XY stage, the LMS-6000SF variant can perform automated 5&#215;5 or 9&#215;9 grid uniformity scans, outputting delta-E values per measurement point. A delta-E value exceeding 3 across the display is often flagged as a visual non-conformity in high-end consumer electronics.<\/p>\n<p><strong>6. Photovoltaic Industry: Spectral Responsivity and Quantum Efficiency Correlation<\/strong><\/p>\n<p>While not a primary light source, photovoltaic (PV) cells are characterized by their spectral response. The LMS-6000UV spectroradiometer, covering the UV and visible spectrum, is used to measure the spectral irradiance distribution of solar simulators per IEC 60904-9.<\/p>\n<p>A PV cell\u2019s spectral mismatch correction factor (MMF) must be calculated by comparing the test solar simulator\u2019s SPD to the AM1.5G reference spectrum. Using the LMS-6000UV, QC technicians measure the simulator\u2019s SPD between 300 and 1100 nm at 1 nm intervals. The instrument\u2019s UV sensitivity\u2014down to 200 nm\u2014is essential for characterizing CdTe or CIGS thin-film cells, which have a sharp spectral response cutoff in the UV-blue region. The data allows for the calculation of the spectral mismatch parameter (S) with an accuracy of \u00b10.5%, directly impacting the reported efficiency of the PV device.<\/p>\n<p><strong>Table 1: Specifications of LISUN LMS-6000 Variants Relevant to QC Applications<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left\">Variant<\/th>\n<th style=\"text-align: left\">\u6ce2\u9577\u7bc4\u56f2<\/th>\n<th style=\"text-align: left\">Key Application Area<\/th>\n<th style=\"text-align: left\">Photometric Range<\/th>\n<th style=\"text-align: left\">Dominant Wavelength Accuracy<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left\">LMS-6000<\/td>\n<td style=\"text-align: left\">380\u2013780 nm<\/td>\n<td style=\"text-align: left\">General LED QC, Lighting<\/td>\n<td style=\"text-align: left\">0.01\u2013200,000 cd\/m\u00b2<\/td>\n<td style=\"text-align: left\">\u00b10.3 nm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\">LMS-6000F<\/td>\n<td style=\"text-align: left\">380\u2013780 nm<\/td>\n<td style=\"text-align: left\">Automotive, Fiber-coupled<\/td>\n<td style=\"text-align: left\">0.01\u2013100,000 cd\/m\u00b2<\/td>\n<td style=\"text-align: left\">\u00b10.3 nm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\">LMS-6000S<\/td>\n<td style=\"text-align: left\">380\u2013780 nm<\/td>\n<td style=\"text-align: left\">Solid-state lighting binning<\/td>\n<td style=\"text-align: left\">0.1\u2013500,000 cd\/m\u00b2<\/td>\n<td style=\"text-align: left\">\u00b10.3 nm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\">LMS-6000P<\/td>\n<td style=\"text-align: left\">380\u2013780 nm<\/td>\n<td style=\"text-align: left\">Display probe measurement<\/td>\n<td style=\"text-align: left\">0.001\u201350,000 cd\/m\u00b2<\/td>\n<td style=\"text-align: left\">\u00b10.3 nm<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\">LMS-6000UV<\/td>\n<td style=\"text-align: left\">200\u20131100 nm<\/td>\n<td style=\"text-align: left\">PV, UV curing, medical<\/td>\n<td style=\"text-align: left\">0.01\u2013200,000 cd\/m\u00b2<\/td>\n<td style=\"text-align: left\">\u00b10.3 nm (Visible)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\">LMS-6000SF<\/td>\n<td style=\"text-align: left\">380\u2013780 nm<\/td>\n<td style=\"text-align: left\">Scan\/flexible display test<\/td>\n<td style=\"text-align: left\">0.001\u201350,000 cd\/m\u00b2<\/td>\n<td style=\"text-align: left\">\u00b10.3 nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>7. Optical Instrument R&amp;D and Scientific Research Laboratories: Radiometric Calibration Standards<\/strong><\/p>\n<p>In research environments, spectroradiometers are used as primary transfer standards for calibrating other photometric instruments. The LMS-6000 platform supports this role through its extended calibration stability. The temperature-stabilized detector and double monochromator maintain a spectral irradiance scale with a drift of less than 0.5% per year.<\/p>\n<p>For researchers analyzing electroluminescence spectra of quantum dot materials or perovskite LEDs, the PMT-equipped variant offers a dynamic range that captures both the high-intensity peak and the low-intensity tail states, which are indicative of trap densities. The instrument\u2019s ability to output raw spectral data (W\/sr\/m\u00b2\/nm) allows for recalculation of any photometric or colorimetric quantity without post-processing artifacts. Furthermore, the integration with LabVIEW or Python-based scripting enables automated acquisition synchronization with source measure units (SMUs) for current-voltage-luminance (JVL) characterization.<\/p>\n<p><strong>8. Urban Lighting Design and Mesopic Photometry Verification<\/strong><\/p>\n<p>Urban lighting design under CIE 191:2010 incorporates mesopic photometry, which accounts for rod-cone interaction at intermediate light levels (0.005 to 5 cd\/m\u00b2). Traditional photometers calibrated for photopic vision are inadequate for this regime.<\/p>\n<p>The LMS-6000 series measures the true SPD of a luminaire, from which the S\/P (scotopic\/photopic) ratio is computed. A high S\/P ratio (&gt;2.0) indicates that a lamp emits more short-wavelength light, which is beneficial for peripheral vision under mesopic conditions. QC verification involves confirming that the as-installed luminaire\u2019s SPD matches the design specification within \u00b13% spectrally. The instrument\u2019s low-luminance sensitivity ensures that measurements taken at typical roadway distances (10\u201320 meters) are statistically valid, allowing for accurate calculation of the mesopic luminance factor and the resulting visibility level (VL).<\/p>\n<p><strong>9. Marine and Navigation Lighting: Environmental Robustness and Chromaticity Stability<\/strong><\/p>\n<p>Marine navigation lights\u2014per COLREGS and IALA recommendations\u2014must maintain chromaticity over a wide temperature range (-30\u00b0C to +55\u00b0C) and in high-humidity conditions. The LMS-6000 spectroradiometer is used in environmental chambers to measure the SPD of a light source at temperature extremes.<\/p>\n<p>For example, a white navigation light must remain within the white chromaticity trapezoid, even when the LED junction temperature rises by 40\u00b0C due to solar loading. The instrument\u2019s high-speed measurement (3 seconds per scan) allows for dynamic thermal testing, capturing the SPD at each 5\u00b0C increment during a temperature ramp. The derived CCT shift per degree Celsius (\u0394CCT\/\u0394T) is a key QC metric; any non-linear behavior suggests a failure in the thermal management or phosphor material. The system\u2019s data logging software automatically generates a report comparing the measured points to the IALA E-200-8 chromaticity limits.<\/p>\n<p><strong>10. Stage and Studio Lighting: DMX-Controlled Color Mixing Accuracy<\/strong><\/p>\n<p>Entertainment lighting relies on additive color mixing (RGB, RGBW, or RGBAW). The LMS-6000S is used to calibrate and verify the color output of moving heads and LED arrays.<\/p>\n<p>QC in this industry focuses on repeating a programmed color across multiple fixtures. By measuring the SPD of each fixture at 256 DMX levels, the technician creates a custom calibration file that corrects for variations in LED binning. The instrument calculates the shift in delta-E between fixtures for a given DMX value; a delta-E of less than 2 is the industry standard for \u201ccolor matching\u201d in television productions. The spectroradiometer\u2019s ability to measure flicker percentage (through the Flicker Index calculation, derived from the SPD envelope under pulsed driving conditions) is also critical for ensuring that camera systems do not exhibit rolling shutter artifacts.<\/p>\n<p><strong>11. Medical Lighting Equipment: Endoscopy and Surgical Illumination Spectral Safety<\/strong><\/p>\n<p>Medical lighting\u2014specifically surgical task lights and endoscope illumination\u2014must meet ISO 15004-2 for photobiological safety. The LMS series evaluates the retinal hazard-weighted radiance (blue light hazard) of a light source.<\/p>\n<p>The instrument quantifies the weighted irradiance (J(\u03bb) <em> E(\u03bb) <\/em> d\u03bb) from 300 to 700 nm. A critical parameter for endoscopic light sources is the ratio of blue light hazard to illumination power. If this ratio exceeds 0.03, the source is classified as a Group 2 risk. The LMS-6000\u2019s spectral resolution ensures that the sharp cutoff filters in modern LED surgical lights are characterized with sub-nanometer accuracy, preventing an overestimation of hazard by broadband sensors. Additionally, for photodynamic therapy (PDT) devices, the spectroradiometer verifies that the spectral output is within the 630 nm \u00b1 5 nm activation window required for Photosensitizer activation.<\/p>\n<p><strong>12. Competitive Advantages of the LISUN LMS-6000 Platform for Multi-Industry QC<\/strong><\/p>\n<p>Compared to scanning spectroradiometers with rotating grating technology, the LMS-6000 series offers a distinct advantage in measurement speed and stray light management. The double monochromator design yields a stray light level of \u22641\u00d710\u207b\u2075, which is approximately one order of magnitude lower than typical single-grating instruments. This is crucial when measuring the red tail of a white LED only a few nanometers away from a strong blue pump peak.<\/p>\n<p>Furthermore, the platform supports a wide dynamic input\u2014ranging from 0.01 lx to 200,000 lx for illuminance\u2014without the need for external neutral density filters that would compromise calibration. The instrument\u2019s firmware includes automated calibration to self-restore baseline characteristics after power cycles, minimizing operator-induced error in high-throughput production lines.<\/p>\n<p><strong>Table 2: Stray Light Comparison for LED Peak Measurement Accuracy<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left\">Instrument Class<\/th>\n<th style=\"text-align: left\">Stray Light Level<\/th>\n<th style=\"text-align: left\">Measured CCT Error (for 6500K White LED)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left\">Single Monochromator<\/td>\n<td style=\"text-align: left\">~1\u00d710\u207b\u00b3<\/td>\n<td style=\"text-align: left\">\u00b1100 K<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\"><strong>LISUN LMS-6000<\/strong><\/td>\n<td style=\"text-align: left\"><strong>\u22641\u00d710\u207b\u2075<\/strong><\/td>\n<td style=\"text-align: left\"><strong>\u00b115 K<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\">Double Monochromator (High-End)<\/td>\n<td style=\"text-align: left\">&lt;1\u00d710\u207b\u2076<\/td>\n<td style=\"text-align: left\">\u00b15 K<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The data in Table 2 illustrates that for standard QC binning where a tolerance of \u00b150 K is acceptable, the LMS-6000 series provides more than sufficient margin. For research applications, the lower stray light ensures that color rendering index calculations, which are highly sensitive to spectral shape, are free from systematic bias.<\/p>\n<p><strong>13. Integration with Automated QC Workflows<\/strong><\/p>\n<p>The LMS-6000 series is equipped with USB, RS-232, and optional GPIB interfaces, allowing direct connection to PLCs and automated handling systems. For example, in an LED production line, the spectroradiometer can be triggered by a photoelectric sensor when a component is aligned at the measurement station. The device performs a 5-second scan, calculates the CCT and chromaticity coordinates, and outputs a TTL signal indicating \u201cPass\u201d or \u201cFail.\u201d The instrument\u2019s API supports common programming languages (C++, Python, LabVIEW), enabling custom data logging and statistical process control (SPC) chart generation.<\/p>\n<p>The software suite provided by LISUN also includes a report generator that complies with IES LM-79-19 for electrical and photometric testing of solid-state lighting products. This report includes the measured SPD, LER (Luminous Efficacy of Radiation), CRY (Correlated Color Temperature), and Duv (distance from blackbody locus), all computed automatically without user intervention.<\/p>\n<p><strong>\u7d50\u8ad6<\/strong><\/p>\n<p>Advanced light and color measurement for quality control demands more than basic photometry; it requires spectral intelligence. The LISUN LMS-6000 spectroradiometer series (LMS-6000, LMS-6000F, LMS-6000S, LMS-6000P, LMS-6000UV, and LMS-6000SF) meets this demand through precise spectral scanning, superior stray light rejection, and robust construction suitable for production environments. From automotive headlamp certification and OLED display binning to photobiological safety screening in medical devices, the platform provides the metrological foundation necessary for objective, repeatable quality assurance.<\/p>\n<p><strong>Frequently Asked Questions (FAQ)<\/strong><\/p>\n<p><strong>Q1: How does the LMS-6000 series account for temperature drift during long production runs?<\/strong><br \/>\nThe instrument includes an internal temperature stabilization mechanism for the detector and monochromator housing. It also performs an automatic dark current correction prior to each measurement cycle, which is a subtraction of the detector\u2019s thermal noise baseline. This dual approach maintains spectral accuracy within \u00b10.3 nm even with ambient temperature changes of \u00b15\u00b0C.<\/p>\n<p><strong>Q2: Can the LMS-6000 evaluate flicker in LED lighting according to IEEE 1789?<\/strong><br \/>\nYes. The LMS-6000 variants can capture the time-resolved relative SPD over a period of 1 ms to 10 seconds. Using the software, one can calculate the Flicker Index (FI) and Percent Flicker (%F) from the slow-motion scanning mode. It is important to note that for submicrosecond PWM measurements, an oscilloscope-based photodiode is preferential, but for standard 50\u2013120 Hz flicker, the spectroradiometer provides compliant data.<\/p>\n<p><strong>Q3: What is the correct way to interface the LMS-6000F with a goniophotometer?<\/strong><br \/>\nThe LMS-6000F\u2019s fiber-optic input should be connected to the cosine-corrected receptor (CCR) placed at the turntable of the goniophotometer. The fiber length should not exceed 5 meters to minimize spectral transmission losses in the UV and IR regions. The instrument\u2019s triggering mode should be set to &#8220;Hardware Trigger&#8221; to synchronize with the goniometer\u2019s angular position signals.<\/p>\n<p><strong>Q4: For measuring uv curing intensity, which variant is recommended?<\/strong><br \/>\nThe LMS-6000UV is the appropriate variant. It is calibrated for spectral irradiance from 200 to 400 nm, covering the UVA, UVB, and UVC bands. The instrument can measure the integrated irradiance (mW\/cm\u00b2) and calculate the peak wavelength of the UV LED or mercury lamp. It is critical to use a diffuser designed for UV transmission, as standard quartz diffusers may have a transmission cutoff around 220 nm.<\/p>\n<p><strong>Q5: How frequently should the LMS-6000 be recalibrated for regulatory compliance?<\/strong><br \/>\nFor most QC applications, an annual calibration interval using a NIST-traceable standard lamp is sufficient. However, for laboratories under ISO 17025 accreditation or those performing photobiological testing (IEC 62471), a recalibration interval of 6 months is recommended. The instrument\u2019s self-diagnostic feature, which checks the baseline spectral position against an internal reference, can be performed weekly to ensure no drift has occurred.<\/p>","protected":false},"excerpt":{"rendered":"<p>Title: Advanced Light and Color Meter Applications for Quality Control: Precision Spectroradiometric Analysis with the LISUN LMS-6000 Series Abstract The measurement of light and color parameters is fundamental to quality control (QC) across a spectrum of high-precision industries. Traditional photometric sensors often fail to capture the spectral nuances required for rigorous pass\/fail criteria. This article presents a technical examination of advanced light and color meter applications, focusing on spectroradiometric instrumentation. We detail the operational principles, metrological specifications, and sector-specific use cases of the LISUN LMS-6000 spectroradiometer platform, including its variants (LMS-6000, LMS-6000F, LMS-6000S, LMS-6000P, LMS-6000UV, and LMS-6000SF). The discussion encompasses application in the lighting, automotive, aerospace, display, photovoltaic, and medical [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3419,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[837],"class_list":["post-8706","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs","tag-light-and-color-meter"],"_links":{"self":[{"href":"https:\/\/ledtestsystem.com\/ja\/wp-json\/wp\/v2\/posts\/8706","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ledtestsystem.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ledtestsystem.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ledtestsystem.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ledtestsystem.com\/ja\/wp-json\/wp\/v2\/comments?post=8706"}],"version-history":[{"count":1,"href":"https:\/\/ledtestsystem.com\/ja\/wp-json\/wp\/v2\/posts\/8706\/revisions"}],"predecessor-version":[{"id":8707,"href":"https:\/\/ledtestsystem.com\/ja\/wp-json\/wp\/v2\/posts\/8706\/revisions\/8707"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ledtestsystem.com\/ja\/wp-json\/wp\/v2\/media\/3419"}],"wp:attachment":[{"href":"https:\/\/ledtestsystem.com\/ja\/wp-json\/wp\/v2\/media?parent=8706"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ledtestsystem.com\/ja\/wp-json\/wp\/v2\/categories?post=8706"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ledtestsystem.com\/ja\/wp-json\/wp\/v2\/tags?post=8706"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}