{"id":2736,"date":"2025-06-19T19:39:14","date_gmt":"2025-06-19T11:39:14","guid":{"rendered":"https:\/\/www.ledphotometer.com\/blog\/withdrawal-pull-gauges-for-effectiveness-of-contact-of-bs1363-2-figure-16\/"},"modified":"2025-06-25T15:33:35","modified_gmt":"2025-06-25T07:33:35","slug":"withdrawal-pull-gauges-for-effectiveness-of-contact-of-bs1363-2-figure-16","status":"publish","type":"post","link":"https:\/\/ledtestsystem.com\/es\/productos\/withdrawal-pull-gauges-for-effectiveness-of-contact-of-bs1363-2-figure-16\/","title":{"rendered":"Withdrawal Pull Gauges for Effectiveness of Contact of BS1363-2 Figure 16"},"content":{"rendered":"<p>1) Grounding minimum pull out force gauge (BS1363-2 Figure 16a): By simulating the grounding bolt insert into the socket test samples and imposing the prescribed vertical downward force (poise) to check whether the socket is fits to the standard requirements.<\/p>\n<p>2) Diversion jack minimum pull out force gauge (BS1363-2 Figure 16b): By simulating the bolt of the firing line or zero line to insert into the socket test samples and imposing the prescribed vertical downward force (poise) to check whether the socket is fits to the standard requirements.<\/p>\n<p><strong>1. Aplicaci\u00f3n:<\/strong><br \/>\nEste medidor de prueba para enchufes y tomas de corriente se utiliza principalmente para comprobar si la estructura y el tama\u00f1o de los enchufes y tomas de corriente cumplen con la norma BS 1363. Sus principales aplicaciones se encuentran en los sectores de la electr\u00f3nica, los electrodom\u00e9sticos, los enchufes y tomas de corriente, entre otros.<\/p>\n<p><strong>2. Caracter\u00edsticas:<\/strong><br \/>\nGauge dimensions, tolerances, material, hardness, surface roughness conform to the standards requirements;<br \/>\nMaterial hardness is more than 50HRC; Material thermal expansion coefficient is small,dimensions and tolerances is stable and reliable.<\/p>\n<div id=\"attachment_12912\" class=\"wp-caption aligncenter\" style=\"width: 724px;\">\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-12912 size-full\" src=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/10\/GNGPL-BSF16AB-A24.png\" sizes=\"(max-width: 714px) 100vw, 714px\" srcset=\"https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/10\/GNGPL-BSF16AB-A24.png 714w, https:\/\/www.lisungroup.com\/wp-content\/uploads\/2023\/10\/GNGPL-BSF16AB-A24-308x400.png 308w\" alt=\"\" width=\"714\" height=\"928\" aria-describedby=\"caption-attachment-12912\" title=\"\"><\/p>\n<p id=\"caption-attachment-12912\" class=\"wp-caption-text\"><span style=\"color: #ff0000;\">Withdrawal Pull Gauges for Effectiveness of Contact of BS1363-2 Figure 16<\/span><\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>1) Grounding minimum pull out force gauge (BS1363-2 Figure 16a): By simulating the grounding bolt insert into the socket test samples and imposing the prescribed vertical downward force (poise) to check whether the socket is fits to the standard requirements. 2) Diversion jack minimum pull out force gauge (BS1363-2 Figure 16b): By simulating the bolt [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3283,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[6],"tags":[449],"class_list":["post-2736","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-products","tag-gngpl-3616"],"_links":{"self":[{"href":"https:\/\/ledtestsystem.com\/es\/wp-json\/wp\/v2\/posts\/2736","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ledtestsystem.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ledtestsystem.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ledtestsystem.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ledtestsystem.com\/es\/wp-json\/wp\/v2\/comments?post=2736"}],"version-history":[{"count":0,"href":"https:\/\/ledtestsystem.com\/es\/wp-json\/wp\/v2\/posts\/2736\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ledtestsystem.com\/es\/wp-json\/wp\/v2\/media\/3283"}],"wp:attachment":[{"href":"https:\/\/ledtestsystem.com\/es\/wp-json\/wp\/v2\/media?parent=2736"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ledtestsystem.com\/es\/wp-json\/wp\/v2\/categories?post=2736"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ledtestsystem.com\/es\/wp-json\/wp\/v2\/tags?post=2736"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}